2023-04 |
Design of a Nuclear Monitoring System Based on a Multi-Sensor Network and Artificial Intelligence Algorithm |
Sustainability
|
2023-03 |
Development of a muon detector based on a plastic scintillator and WLS fibers to be used for muon tomography system |
Nuclear Engineering and Technology
|
2023-01 |
Timing pickoff method for improvement of timing resolution in AGPET |
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
|
2022-10 |
Preliminary study of artificial intelligence-based fuel-rod pattern analysis of low-quality tomographic image of fuel assembly |
Nuclear Engineering and Technology
|
2022-08 |
Preliminary results of a single photon emission computed tomography (SPECT) detector for inspection of spent fuel assembly |
RADIATION PHYSICS AND CHEMISTRY
|
2022-07 |
Feasibility study of a prototype muon tomography system based on a plastic scintillator and WLS fibers |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2022-06 |
Experimental evaluation of fuel rod pattern analysis in fuel assembly using Yonsei single-photon emission computed tomography (YSECT) |
NUCLEAR ENGINEERING AND TECHNOLOGY
|
2022-02 |
Design and Characterization of a Muon Tomography System for Spent Nuclear Fuel Monitoring |
NUCLEAR ENGINEERING AND TECHNOLOGY
|
2022-01 |
Design and characterization of a hemispherical monitoring system for large-area radiation monitoring |
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
|
2021-08 |
Performance evaluation of an adjustable gantry PET (AGPET) for small animal PET imaging |
NUCLEAR ENGINEERING AND TECHNOLOGY
|
2021-03 |
Development of de-noised image reconstruction technique using Convolutional AutoEncoder for fast monitoring of fuel assemblies |
NUCLEAR ENGINEERING AND TECHNOLOGY
|
2020-10 |
Feasibility study of multiplexing method using digital signal encoding technique |
NUCLEAR ENGINEERING AND TECHNOLOGY
|
2020-10 |
Feasibility study of SiPM based scintillation detector for dual-energy X-ray absorptiometry |
NUCLEAR ENGINEERING AND TECHNOLOGY
|
2020-02 |
Feasibility of adjustable-gantry PET system using advanced DOI method |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2019-07 |
Optimization of single-photon emission computed tomography system for fast verification of spent fuel assembly: a Monte Carlo study |
JOURNAL OF INSTRUMENTATION
|
2017-10 |
Monte Carlo simulation of secondary neutron dose for scanning proton therapy using FLUKA |
PLOS ONE
|
2017-10 |
Simulation of a Gamma-Ray Computed Tomography System Using Two Radioisotopes for Structural Inspections: A Preliminary Study |
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
|
2017-10 |
A radioactive material monitoring system using multiple gamma spectroscopy detectors and centroid method |
APPLIED RADIATION AND ISOTOPES
|
2017-01 |
A new DOI detector design using discrete crystal array with depth-dependent reflector patterns and single-ended readout |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2016-12 |
Development of a novel depth-of-interaction encoding method and use of light spreading in a scintillation crystal array with single-ended readout |
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
|
2016-10 |
Monte Carlo Modeling of a Novel Depth-Encoding PET Detector with DETECT2000 |
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
|
2016-09 |
Secondary Neutron Dose Measurement for Proton Line Scanning Therapy |
PROGRESS in MEDICAL PHYSICS (PMP)
|
2016-06 |
Preliminary results of a prototype C-shaped PET designed for an in-beam PET system |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2016-05 |
Optimization of proton CT detector system and image reconstruction algorithm for on-line proton therapy |
PLOS ONE
|
2016-05 |
Development of a SiPM-based PET detector using a digital positioning algorithm |
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
|
2015-02 |
Design and Characterization of a Small Muon Tomography System |
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
|
2014-12 |
Development of an All-in-one Gamma Camera/CCD System for Safeguard Verification |
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
|
2014-06 |
A Depth-Encoding PET Detector Inserting Glass Plate Between Crystal Layers |
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
|
2014-05 |
Preliminary studies of PQS PET detector module for dose verification of carbon beam therapy |
JOURNAL OF INSTRUMENTATION
|
2014-05 |
Feasibility Study of a Gamma Camera for Monitoring Nuclear Materials in the PRIDE Facility |
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
|
2013-11 |
Design of a muon tomography system with a plastic scintillator and wavelength-shifting fiber arrays |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2013-11 |
Development of a pinhole gamma camera for environmental monitoring |
RADIATION MEASUREMENTS
|
2013-01 |
Optimization of the Angle between Detector Modules in a Dual-head Cardiac SPECT |
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
|
2013-01 |
Gamma camera with a two-layer diverging-slat collimator for radioisotope monitoring |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2013-01 |
A simulation study of a C-shaped in-beam PET system for dose verification in carbon ion therapy |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2012-01 |
New concept of a range verification system for proton therapy using a photon counting detector |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2012-01 |
Development of a large-angle pinhole gamma camera with depth-of-interaction capability for small animal imaging |
JOURNAL OF INSTRUMENTATION
|
2012-01 |
Free-running ADC- and FPGA-based signal processing method for brain PET using GAPD arrays |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2011-12 |
CMOS APD array for multi-function of both sequential and summing mode operations |
JOURNAL OF INSTRUMENTATION
|
2011-11 |
Performance measurements of a depth-encoding TraPET detector module |
JOURNAL OF INSTRUMENTATION
|
2011-10 |
Design of parallel dual-energy X-ray beam and its performance for security radiography |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2011-10 |
Optimization of a partially segmented block detector for MR-compatible small animal PET |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2011-10 |
TraPET: High performance small animal PET with trapezoidal phoswich detector |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2011-09 |
소동물 폐종양의 정량적 개선을 위한 내부 움직임 평가 |
의학물리
|
2011-06 |
Development of a portable X-ray scan system (PXSS) |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2011-06 |
Nuclear Material Monitoring System (NMMS) for security screens |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2011-06 |
Large-angle pinhole gamma camera with depth-of-interaction detector for contamination monitoring |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2011-06 |
Trapezoidal-shaped detector to reduce edge effects in small gamma camera |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2011-05 |
Performance evaluation of a PET detector consisting of an LYSO array coupled to a 4x4 array of large-size GAPD for MR compatible imaging |
JOURNAL OF INSTRUMENTATION
|
2011-05 |
New design of a gamma camera detector with reduced edge effect for breast imaging |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2011-01 |
Monte Carlo simulation of a four-layer DOI detector with relative offset in animal PET |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2010-09 |
Preliminary experimental results of a quasi-monolithic detector with DOI capability for a small animal PET |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2010-06 |
Optimization of Large-Angle Pinhole Collimator for Environmental Monitoring System |
Ieee Transactions On Nuclear Science
|
2010-01 |
Monte Carlo Simulation on the 4 pi Field of a View Compact Compton Camera by Using Scintillators |
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
|
2009-06 |
Performance evaluation for pinhole collimators of small gamma camera by MTF and NNPS analysis: Monte Carlo simulation study |
Nuclear Instruments & Methods In Physics Research Section A-Accelerators Spectrometers Detectors And Associated Equipment
|
2009-06 |
A Cross-Stack Quasi-Monolithic Detector with DOI Capability for a Small Animal PET |
Journal Of The Korean Physical Society
|
2009-04 |
GATE Simulations of CTDI for CT Dose |
Journal Of The Korean Physical Society
|
2009-01 |
Characterization and Optimization of a Quasi-Monolithic Detector Module with Depth-Encoding for Small Animal PET |
Journal Of The Korean Physical Society
|
2008-12 |
배열형 섬광결정을 이용한 소형 감마카메라의 평행구멍형 조준기 최적화 연구 |
의학물리
|
2008-12 |
갑상선 영상 획득을 위한 부호화 구경 감마카메라: 몬테칼로 시뮬레이션 연구 |
의학물리
|
2008-07 |
New design of a quasi-monolithic detector module with DOI capability for small animal pet |
Nuclear Instruments & Methods In Physics Research Section A-Accelerators Spectrometers Detectors And Associated Equipment
|
2008-05 |
Monte Carlo simulation codes for nuclear medicine imaging |
핵의학 분자영상
|
2007-01 |
Optimization of LSO/LuYAP phoswich detector for small animal PET |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
|
2005-04 |
Optimization of dual layer phoswich detector consisting of LSO and LuYAP for small animal PET |
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
|
2004-11 |
Performance improvement of small gamma camera using NaI(Tl) plate and position sensitive photo-multiplier tubes |
PHYSICS IN MEDICINE AND BIOLOGY
|
2004-10 |
GATE: a simulation toolkit for PET and SPECT |
PHYSICS IN MEDICINE AND BIOLOGY
|
2004-04 |
분자영상 획득을 위한 핵의학 영상기기 |
핵의학 분자영상
|
2004-02 |
소동물 Iodine-125 SPECT 개발을 위한 컴퓨터 시뮬레이션 |
핵의학 분자영상
|
2004-01 |
Evaluation of maximum-likelihood position estimation with Poisson and Gaussian noise models in a small gamma camera |
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
|
2003-04 |
Optimization of pinhole collimator for small animal SPECT using Monte Carlo simulation |
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
|
2001-04 |
Monte Carlo analyses of X-ray absorption, noise and detective quantum efficiency considering therapeutic X-ray spectrum in portal imaging detector |
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
|
2000-04 |
Characterization of X-ray detector for CCD-based electronic portal imaging device |
의공학회지
|
1999-02 |
Monte Carlo studies of metal/phosphor screen in therapeutic X-ray imaging |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SP
|